Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Perinat Med ; 48(1): 67-73, 2019 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-31677377

RESUMO

Objective To reveal the effect of a maternal human immunodeficiency virus (HIV) infection on the fetal thymus size. Methods The sonographic fetal thymus size was measured retrospectively in 105 pregnancies with maternal HIV infection and in 615 uncomplicated singleton pregnancies. The anteroposterior thymic and the intrathoracic mediastinal diameter were determined in the three-vessel view and their quotient, the thymic-thoracic ratio (TT ratio), was calculated. The study group was subdivided into three groups by the maternal viral load on the date of ultrasound (<50 cop./mL, 50-1000 cop./mL, >1000 cop./mL). Furthermore, an association between prognostic factors of the HIV infection such as the lymphocyte count, CD4/CD8 ratio, HIV medication and the thymus size, was investigated using correlation analyses. Results Fetal thymus size in pregnancies of HIV-positive mothers showed to be noticeably larger than in uncomplicated pregnancies. The mean TT ratio in the HIV-positive group was 0.389 and in the control group 0.345 (P < 0.001). There was no association between any maternal HIV parameter or medication and the size of the thymus gland. Conclusion Maternal HIV infection was associated with an increased fetal thymus size. Further consequences of intrauterine HIV exposure for fetal outcome and the development of the immune system of HIV-exposed uninfected (HEU) infants must be discussed.


Assuntos
Feto/diagnóstico por imagem , Infecções por HIV/diagnóstico por imagem , Complicações Infecciosas na Gravidez/diagnóstico por imagem , Timo/diagnóstico por imagem , Estudos de Casos e Controles , Feminino , Humanos , Tamanho do Órgão , Gravidez , Ultrassonografia Pré-Natal
2.
J Perinat Med ; 47(9): 941-946, 2019 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-31562804

RESUMO

Background The aim of this study was to compare the adrenal gland size of fetuses of women with gestational diabetes mellitus (GDM) with that of healthy control fetuses. Methods This prospective cross-sectional study included measurements of the adrenal gland size of 62 GDM fetuses (GDM group) and 370 normal controls (control group) between the 19th and 41st week of gestation. A standardized transversal plane was used to measure the total width and the medulla width. The cortex width and an adrenal gland ratio (total width/medulla width) were calculated from these data. Adrenal gland size measurements were adjusted to the week of gestation and compared between the two groups in a multivariable linear regression analysis. A variance decomposition metric was used to compare the relative importance of predictors of the different adrenal gland size measurements. Results For all the investigated parameters of the adrenal gland size, increased values were found in the case of GDM (P < 0.05), while adjusting for the week of gestation. GDM seems to have a greater impact on the size of the cortex than on the size of the medulla. Conclusion The fetal adrenal gland is enlarged in pregnancy complicated by GDM. The width of the cortex seems to be particularly affected.


Assuntos
Glândulas Suprarrenais/embriologia , Diabetes Gestacional/fisiopatologia , Desenvolvimento Fetal , Glândulas Suprarrenais/diagnóstico por imagem , Glândulas Suprarrenais/patologia , Estudos de Casos e Controles , Estudos Transversais , Diabetes Gestacional/diagnóstico por imagem , Feminino , Idade Gestacional , Humanos , Modelos Lineares , Análise Multivariada , Gravidez , Estudos Prospectivos , Ultrassonografia Pré-Natal
3.
J Perinat Med ; 47(8): 811-816, 2019 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-31503543

RESUMO

Background The aim of this study was to compare transabdominal and transcervical chorionic villus sampling (CVS) as well as amniocentesis (AC) with respect to their rates of premature delivery and fetal growth restriction. Methods We retrospectively evaluated the mentioned procedures of invasive prenatal testing performed in a single center between 2001 and 2016. Seven hundred and ninety-nine cases of AC and 719 cases of CVS were included, of which 400 were performed transvaginally. Only singleton pregnancies with a normal karyotype and delivery after 24 + 0 weeks of gestation were included. Fetal growth restriction was defined as birth weight below the 10th percentile. Premature delivery was defined as delivery before 37 + 0 weeks of gestation. Data were compared to a control group without an invasive procedure. Results The frequency of premature delivery was 8.5% after transabdominal CVS, 6.3% after transcervical CVS and 10.5% after AC as compared to 10.8% in the control group. The frequency of fetal growth restriction was 8.2% after transabdominal CVS 6.8% after transcervical CVS and 8.4% after AC as compared to 9.7% in the control group. Conclusion Our study supports that the three different methods of invasive prenatal testing do not lead to a higher risk of either premature delivery or fetal growth restriction when compared to controls. We found no difference in risk profile among the three techniques.


Assuntos
Amniocentese/efeitos adversos , Amostra da Vilosidade Coriônica/efeitos adversos , Retardo do Crescimento Fetal/etiologia , Nascimento Prematuro/etiologia , Adulto , Feminino , Humanos , Gravidez , Estudos Retrospectivos
4.
Ultrasound Med Biol ; 45(1): 233-245, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30482712

RESUMO

The aim of our prospective pilot study with exploratory analysis was to compare longitudinal and apical foetal speckle tracking echocardiography (STE) using tissue motion annular displacement (TMAD) and segmental longitudinal strain (SLS). We compared two different STE quantification tools in a longitudinal and apical four-chamber view in 57 normal foetuses between 20 and 40 wk of gestation. Myocardial mechanical dyssynchrony and strain were assessed using offline quantification software (QLab Version 10.3, Philips Medical Systems, Andover, MA, USA). We compared the dyssynchrony measurements with TMAD and SLS in longitudinal and apical four-chamber views. Furthermore, we examined the segmental strain values of both ventricles with SLS and compared the differences between longitudinal and apical measurements. Dyssynchrony measurements with TMAD and SLS and strain measurements with SLS were feasible in all cases. In the apical view, the dyssynchrony measurements with TMAD were systematically greater than those achieved with SLS (p < 0.001). For the longitudinal view, no differences were observed between tools (p = 0.153). The application of SLS provided similar results for dyssynchrony in both views (intra-class correlation coefficient [ICC] = 0.281, p = 0.623), but the strain measurements in the left and right ventricles differed significantly between views (ICC = -0.082, p = 0.011, and ICC = -0.061, p = 0.024, respectively). For TMAD, we found large differences in the dyssynchrony values between longitudinal and apical assessment (ICC = -0.060, p = 0.03). Furthermore, TMAD exhibited reduced accuracy in the system's automatic tracking algorithm, limiting the data quality. The dyssynchrony assessment is affected less by the foetal position in SLS than in TMAD. The strain readings in SLS varied depending on the view in which they were assessed. The application of TMAD cannot be recommended for foetal STE.


Assuntos
Ecocardiografia/métodos , Coração Fetal/diagnóstico por imagem , Coração Fetal/fisiopatologia , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Ultrassonografia Pré-Natal/métodos , Adulto , Estudos de Coortes , Estudos Transversais , Feminino , Cardiopatias Congênitas/embriologia , Humanos , Projetos Piloto , Gravidez , Estudos Prospectivos , Reprodutibilidade dos Testes
5.
J Perinat Med ; 46(8): 900-904, 2018 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-29543592

RESUMO

Objective To compare the adrenal gland size of fetal growth restricted (FGR) and normal control fetuses. Study design In this prospective study the adrenal gland size of 63 FGR fetuses and 343 normal controls was measured between 20 and 41 weeks of gestation. The total width and the medulla width were measured in a new standardized transversal plane. The cortex width and a calculated ratio of the total and medulla width (adrenal gland ratio) were compared between both groups. Results The mean cortex width and the adrenal gland ratio in FGR fetuses were higher in comparison to the controls (P<0.001; P=0.036, respectively). The cortex width correlated positively with the gestational age (control group: P<0.001; FGR group: P=0.089) whilst the adrenal gland ratio showed no association with the gestational age (control group: P=0.153; FGR group: P=0.314). Conclusion The adrenal gland cortex width and the adrenal gland ratio were increased in FGR fetuses compared to normal fetuses.


Assuntos
Glândulas Suprarrenais/diagnóstico por imagem , Retardo do Crescimento Fetal/diagnóstico por imagem , Estudos de Casos e Controles , Feminino , Humanos , Gravidez , Ultrassonografia Pré-Natal
6.
Acta Obstet Gynecol Scand ; 95(2): 210-6, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26445297

RESUMO

INTRODUCTION: We investigated the reliability of fetal thymus measurement during first-trimester screening, and associated fetal thymus size with crown-rump length, maternal diseases and fetal outcome. MATERIAL AND METHODS: In a retrospective cohort of 971 normal singleton first-trimester fetuses, we measured the anterior-posterior diameter of the thymus in a midsagittal plane in 767 fetuses. The intra-observer and inter-observer reliabilities were tested by intra-class correlation coefficient. We correlated thymus size with fetal crown-rump length, and investigated its association with maternal diseases (diabetes mellitus, rheumatic disorders, hypertension and coagulation disorders) and fetal outcome (small for gestational age, preterm birth and umbilical artery pH) using regression analyses. RESULTS: The intra-observer and inter-observer reliabilities of fetal thymus measurement were excellent (intra-class correlation coefficient 0.926, 95% CI 0.745-0.981 and 0.945, 95% CI 0.886-0.993, respectively). A linear relationship was found between crown-rump length and thymus size (ß = 0.023, p = 0.001). Pregnancies affected by maternal diabetes had a decreased fetal thymus size (ß = -0.209, p = 0.001), whereas in pregnancies affected by maternal rheumatic disease the thymus size was increased (ß = 0.285, p < 0.001). Fetal thymus size was not associated with maternal hypertension or maternal coagulation disorders. There was a positive association between preterm birth and fetal thymus size (p < 0.001). CONCLUSION: Measurement of first-trimester thymus size is reliable. Fetal thymus size has a linear correlation with crown-rump length. Maternal diabetes, rheumatic disease and preterm birth appear to have an association with fetal thymus size.


Assuntos
Doenças Fetais/diagnóstico por imagem , Complicações na Gravidez , Timo/diagnóstico por imagem , Timo/embriologia , Ultrassonografia Pré-Natal , Estatura Cabeça-Cóccix , Diabetes Gestacional , Feminino , Humanos , Concentração de Íons de Hidrogênio , Recém-Nascido , Tamanho do Órgão , Gravidez , Primeiro Trimestre da Gravidez , Nascimento Prematuro , Reprodutibilidade dos Testes , Estudos Retrospectivos , Doenças Reumáticas , Fatores de Risco , Artérias Umbilicais
7.
J Perinat Med ; 42(5): 635-9, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24552965

RESUMO

OBJECTIVE: To determine whether certain rheumatic diseases will affect the fetal thymus diameter when compared to uncomplicated singleton pregnancies. Additionally, we created a reference chart for fetal thymus size in healthy singleton pregnancies from 19 to 37 weeks of gestation. METHODS: Sonographic fetal thymus size was retrospectively evaluated in 190 healthy pregnant women, and 84 pregnancies of mothers suffering from systemic lupus erythematosus, antiphospholipid syndrome (APS), or Sjögren's syndrome between 19 and 37 weeks of gestation. These fetuses were matched one-to-one for gestational age with control fetuses. The thymic-thoracic ratio (TT-ratio) was defined as the quotient of the anteroposterior thymic and the intrathoracic mediastinal diameter. RESULTS: Rheumatic diseases often affect pregnancy outcome, especially in case of primary APS. The TT ratio of fetuses of mothers suffering from rheumatic disease was equal to controls (P=0.807). CONCLUSIONS: Ours is the first study to assess the correlation of fetal thymus size in high-risk pregnancies with rheumatic diseases in comparison to controls. Women with rheumatic diseases deal with pregnancy complications more frequently than controls. Our data suggest that maternal rheumatic diseases do not affect the fetal thymus size.


Assuntos
Feto/patologia , Complicações na Gravidez , Doenças Reumáticas/complicações , Timo/diagnóstico por imagem , Síndrome Antifosfolipídica/complicações , Estudos de Casos e Controles , Feminino , Idade Gestacional , Humanos , Lúpus Eritematoso Sistêmico/complicações , Tamanho do Órgão , Gravidez , Valores de Referência , Estudos Retrospectivos , Fatores de Risco , Síndrome de Sjogren/complicações , Tórax/diagnóstico por imagem , Ultrassonografia Pré-Natal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...